14.11 Device Related Diagnostic Data
16 bit
Byte 2, 3
Pump Model and Head
16 bit
Byte 3,4
Tubing Size
16 bit
Byte 5,6
Min Speed (unsigned)
16 bit
Byte 7,8
Max Speed (unsigned)
32 bit
Byte 9,10, 11, 12
Software Version Main CPU
32 bit
Byte 13, 14, 15, 16 Software Version HMI CPU
32 bit
Byte 17, 18, 19, 20 Software Version Flash
32 bit
Byte 21, 22, 23, 24 Software version PROFIBUS CPU
14.12 Channel Related Diagnostic Data
Channel related diagnostic blocks are always three bytes long in the following format:
Byte 1
Header
Byte 2
Channel type
Byte 3
Channel Related Error Code
Channel Related Diagnostic Data
Byte 3
Global error
=0xA9 (General error)
Over current
=0xA1 (Short circuit)
Under voltage
=0xA2 (Under voltage)
Over voltage
=0xA3 (Over voltage)
Over temp
=0xA5 (Over temp)
Motor stall
=0xA4 (Overload)
Tacho fault
=0xB1 (Device related 0x11)
Leak detected
=0xB2 (Device related 0x12)
Setpoint out of range- low
=0xA8 (Lower limit exceeded)
Setpoint out of range- high
=0xA7 (Upper limit exceeded)
Fluid level alert
=0xB3 (Device related 0x15)