MAINTENANCE
44
17.
Put the hose pump on two blocks, on its side as
shown.
18.
Fit the pump drive (A) with the nuts (B) and
washers (C). Make sure the coupling and rotor
are correctly oriented such that they fit onto
each other. Tighten to the specified torque
settings. Refer to §
11.1.6
.
19.
Put the hose pump upright on the support.
20.
Refit the cover (B). Make sure that the eight
bolts (A) are refitted and that they are tightened
in the correct order, diagonally opposite each
other. Refer to §
11.1.6
.
21.
Switch on the electrical supply to the pump.
22.
Fit the (new) pump hose. Refer to §
8.5.3
.
8.7
Fitting options
8.7.1
Fitting a high-level float switch
1.
Dismount the standard breather (A) on the
cover of the pumphead.
B
C
A
A
B
A