MAINTENANCE
40
4.
Check that the rubber bushes (A) are not
deformed or damaged and replace them if
necessary.
5.
Check that the hose clamps (B) are not
damaged and replace them if necessary.
6.
First fit the inlet port.
Slide the rubber bush (D) over the hose. Push
the bracket (A) and the hose clamp (B) over the
hose together. Align the holes in the bracket
with the ones at the front of the port. Position
the two bolts (C) and tighten them. Make sure
the bolts are tightened to the correct torque.
Refer to §
11.1.6
.
7.
Turn the rotor in such a way that the hose (A) is
pressed firmly against the bracket (B).
8.
Place the hose clamp accurately on the track in
the rubber bush. Tighten the bolt (B) of the hose
clamp (A). Make sure the bolt is tightened to the
correct torque. Refer to §
11.1.6
.
9.
Now fit the other port in the same way.
10.
Fill the pump housing with Bredel Genuine
Hose Lubricant. Refer to §
8.4
.
11.
Connect the suction and discharge lines.
B
A
B
A
A
D
C
C
B
A
B
B
A
B
A