INSTALLATION

23

5.3.4

Motor

The motor connection must meet the local applicable
regulations. A thermal safety device should reduce the
risk of a motor overload. For connecting PTC
thermistors (if present) a special thermistor relay must
be used. In case of doubt, contact your Bredel
representative for advice. Refer to §

11.3

for

specifications.
Refer to the documentation supplied with the electric
motor for information on how to connect the motor to
your power supply.

5.3.5

Frequency controller

If the hose pump is fitted with a frequency controller,
consider the following points:

Take precautions so the motor does not restart
automatically after an unscheduled stop.
In the event of a power or mechanical failure,
the frequency controller stops the motor. When
the cause of the failure is removed, the motor
can restart automatically. The automatic restart
can be dangerous in certain pump installations.

F2

F1

F3

Maximum permissible loads [N] on the

pump connections

Force

APEX10, 15, 20

F1

600

F2

120

F3

300

WARNING
A frequency controller that is fitted without
manual control
can start the pump
automatically when power is applied.