Watson-Marlow 120 IP31 pumps: general information

7

Power supply specifications

Insulation category

Class II: double insulated, no earth

Mains voltage/frequency

90-264VAC, 47-63Hz, 1ph

Mains current

0.7A @ 100VAC; 0.4A @ 230VAC

Output voltage

24VDC

Output power

24W @ 30C; 18W @ 40C

Protection

Hiccup mode: recovers automatically after fault removed

Overload protection

110%-200% of rated output power

Working temperature

-10C to 50C, 14F to 122F

Operating humidity

20% to 90% RH, non-condensing

Over-voltage

115% to 135%

Note: Pump specifications are included in Section 2
of these instructions.

1.8 Good pump
installation practice

1.8.1 General
recommendations

Position

The 120 pump must be mounted in the upright posi-
tion and not inverted or placed on its rear face.

A correctly engineered installation will promote long
tube life. Site the pump on a flat, horizontal, rigid
surface, free from excessive vibration, to ensure
correct lubrication of the gearbox. Allow a flow of air
around the pump to ensure that heat can be dissi-
pated. Ensure that the temperature around the
pump does not exceed 40C.

It is possible to stack only one other 120 pump on
top of this pump. The case’s third row of feet ensure
ventilation between pumps and allow the top pump
to be set back a little to give clear access to the
lower pump’s keypad. You can place other equip-
ment on the pump’s upper surface as long as the
ambient temperature does not exceed 40C.

Emergency disconnection

The pump's external DC power supply is the discon-
necting device, which must be readily identifiable
and easily reached, for isolating the motor drive
from the mains supply. Note: There may be a slight
delay after isolating the pump before the pump
stops.