beautypg.com

1 pump specifications – Watson-Marlow 120U/D1 User Manual

Page 16

background image

Watson-Marlow 120U IP31 pumps: operating instructions

2

2.1 Pump
specifications

A nameplate is fixed to the rear of the pump. It con-
tains manufacturer and contact details, product ref-
erence number, serial number and model details.

120U

This pump can be controlled from the keypad or
remotely. It features:
Manual control

Speed adjustment; run and stop; direction con-
trol; “max” key for rapid priming; “auto start”
for automatic power recovery; “auto” key for
changing between manual and auto control

Remote digital control

The pump can be digitally controlled with a
contact closure or logic input signal

Analogue control

The pump speed can be controlled through an
analogue signal input of 4-20mA or 0-10V

Outputs

Logic output designated for an alarm only
DC Tacho output

Pump specifications

Control range (turndown ratio)

Manual control:

With 102R: 0.1-32 rpm (320:1)

With 114DV: 0.1-200 rpm (2,000:1)
With 400D1: 0.1-200 rpm (2,000:1)

With 400DM2: 0.1-100 rpm (1,000:1)
With 400DM3: 0.1-100 rpm (1,000:1)

Auto control:

With 102R: 0.01-32 rpm (3,200:1)

With 114DV: 0.01-200 rpm (20,000:1)
With 400D1: 0.01-200 rpm (20,000:1)

With 400DM2: 0.01-100 rpm (10,000:1)
With 400DM3: 0.01-100 rpm (10,000:1)

Power supply DC input

24V @ 1A

Software version

Accessible through combination keypress

Enclosure rating

IP31 to BS EN 60529. Equivalent to NEMA 2, suiable for indoor

use. Protected against dripping water and falling dirt. May be

wiped with a damp cloth, but should not be immersed

Pumphead options

114DV, 102R, 400D1, 400DM2 and 400DM3

Operating temperature range

5C to 40C, 41F to 104F

Storage temperature range

-25C to 65C, -13F to 149F

Maximum altitude

2,000m, 6,560ft

Humidity (non-condensing)

80% up to 31C, 88F, decreasing linearly to 50% at 40C, 104F

Weight

See Section 1, General information

Noise

<60dB(A)

Function comparison, models 101U and 120U

Function

101U

120U

Analogue
input

0-30mA and
0-30V

4-20mA and 0-10V

Range and
off-set
trimming

possible

can only set the
maximum speed

Signal
inversion

possible

not possible

Tacho
output

+5V and –5V at
maximum speed

5V at maximum
allowed speed

Input
impedance

255

Ω

250

Ω

Max speed
options

2 rpm or
32 rpm, model-
dependant

single speed range,
pumphead-
dependant

Speed
increments

10% or 1%
increments

0.1 rpm in manual
mode and 0.01 rpm
in analogue mode

Analogue
control

2,000:1
control ratio

20,000:1
control ratio

This manual is related to the following products: