Verilink SCC 2020 (880-503268-001) Product Manual User Manual
Page 48

Configuration
3-26
Verilink SCC 2020 User Manual
41
SCC 2020
TAC 2010
Canned configuration #2, EQPT=ESF/AMI NET=ESF/AMI
42
SCC 2020
TAC 2010
Canned configuration #3, EQPT=SF/AMI NET=ESF/B8ZS
43
SCC 2020
TAC 2010
Canned configuration #4, EQPT=SF/B8ZS NET=ESF/B8ZS
44
SCC 2020
TAC 2010
Canned configuration #5, EQPT=ESF/B8ZS NET=ESF/B8ZS
45
—
Not applicable (The SCC does not support storing and restoring
module configurations as the older NCC node controller modules did)
46
—
Not applicable (The SCC does not support storing and restoring
module configurations as the older NCC node controller modules did)
47
SCC 2020
TAC 2010
TAC 2130
Network LBO = 0 dB; Typical value, use when a T1 installed by a local
Bell carrier is terminated in a “smart jack”, (network termination
device) or the first repeater is 2000 to 3000 feet away
48
SCC 2020
TAC 2010
TAC 2130
Network LBO = 7.5 dB; Attenuates transmit signal by 7.5db, USE ONLY
IF NO SMART JACK IS PRESENT , implies that the first active device
(repeater, T3 mux, far CSU) is 1000 to 2000 feet away
49
SCC 2020
TAC 2010
TAC 2130
Network LBO = 15 dB; Attenuates transmit signal by 15db, USE ONLY
IF NO SMART JACK IS PRESENT , implies that the first active device
(repeater, T3 mux, far CSU) is 0 to 1000 feet away
50
SCC 2020
TAC 2010
Selects DSX-1 Equipment cable length of 0-132 ft
51
SCC 2020
TAC 2010
Selects DSX-1 Equipment cable length of 133-265 ft
52
SCC 2020
TAC 2010
Selects DSX-1 Equipment cable length of 266-398 ft
53
SCC 2020
TAC 2010
Selects DSX-1 Equipment cable length of 399-532 ft
54
SCC 2020
TAC 2010
Selects DSX-1 Equipment cable length of 533-655 ft
55
SCC 2020
TAC 2010
Set data bus to NONE (CSU mode) [default]
56
SCC 2020
TAC 2010
DIU 2140
Set data bus to A (Mux mode)
57
SCC 2020
TAC 2010
DIU 2140
Set data bus to B (Mux mode)
Code
Applies to
Description