Configuration
Verilink SCC 2020 User Manual
3-25
Thumbwheel
Procedure
A four-step procedure is used for each thumbwheel command:
1. Set the thumbwheel to the number, 01 through 30, equal to the
slot number of the module to be optioned. If a node consists
of Multi-line shelves, the first slot in shelf two would be
numbered as 14 and the last slot 26. In a node consisting of all
Dual-line shelves, the first (left-hand) slot of a second shelf is
number 03.
2. Rapidly press the EXE pushbutton twice, as if double-clicking a
mouse. If the SCC 2020 accepts your double-click, the STAT
LED on the selected module will begin to blink green to off. If
the STAT LED does not begin to blink try double clicking again
at a slightly faster or slower rate. Do not proceed to step 3
until the STAT LED on the desired module begins to blink.
Once the STAT LED does begin to blink, steps 3 and 4 must be
completed within 60 seconds or the thumbwheel command
procedure will time-out.
3. Set the thumbwheel switches to the command value which is
to be used, per
below.
4. Double-click the EXE pushbutton again. If the SCC 2020
module accepts your double-click, the STAT LED on the
selected module will stop blinking green to off and return to
some other state. If the STAT LED on the module continues to
blink green to off, the SCC 2020 did not accept your double-
click. Try double-clicking again, at a faster or slower rate. If
you are not successful within 60 seconds of the time you
selected the module in step 2, the module will timeout and
return to its normal state. If this happens, start over with step
1 of this procedure.
Thumbwheel
Commands
The chart in
lists the commands available through the
front panel thumbwheels.
Table 3-8
Thumbwheel Switch Commands
Code
Applies to
Description
01 to 30
Any of first
30
modules
Selects a module in the indicated slot, up to slot 30. Thumbwheel
switches cannot be used for modules in slots 31-52
31
SCC 2020
Accesses the controller functionality of the SCC 2020 node controller
(not the T1 CSU portion). For an SCC 2020 in slot 1 of shelf 1, use
address 01 to set CSU options
32
SCC 2020
Reset modem interface by sending the configured modem
initialization string to the DB-9 SLIP port
40 SCC
2020
TAC 2010
Canned configuration #1, EQPT=SF/AMI NET=ESF/AMI