Installing and replacing plug-in modules, Installing a rear connector module into a shelf, Installing a rear connector module into a shelf -1 – Verilink Red Zone Encryption (REMS) (880-502423-001) Product Manual User Manual
Page 91: Chapter

Red Zone Encryption Management System (REMS) User Manual
10-1
Chapter
10
Installing and Replacing Plug-in
Modules
This chapter provides instructions for installing, removing, and replacing
AS2000 modules in their shelves.
CAUTION
Before plugging in modules, be sure shelves are properly installed
and grounded as described in the previous chapter.
Installing a rear connector module into a shelf
To install a rear connector module into a dual-line shelf, use the following
procedure.
Verilink recommends you insert and secure each rear connector module
into its multiline shelf before inserting its mating front modules.
1.
Be sure the power supply cable is unplugged from the rear panel of
the dual-line shelf, or that the power supply is unplugged from the
AC or DC power source.
2.
Select the appropriate shelf and slot position for the rear connector
module/front module 2150 combination. The NCC module goes in
Shelf 0, Slot 1. The DIU module goes in Slot 2.
3.
Orient the rear connector module at the real panel of the dual-line
shelf as shown in Figure 10-1, Front Module and Rear Connector
Module Installation in a Dual-line Shelf, Top View.
TIP