Verilink Red Zone Encryption (REMS) (880-502423-001) Product Manual User Manual
Page 68

Configuring and starting REMS
6-8
Red Zone Encryption Management System (REMS) User Manual
“Solid Red” events take priority over “Flashing Red” events, except
when a loopback is enabled.
Decoding the NCC 2020 CSU Status (STAT) LED Indicator
The STAT (CSU status) LED is a three-color indicator with six possible
states. This will be the only LED lit when the power-up self test fails.
Solid Green
All OK
Flashing Green
The NCC is being accessed by a thumbwheel
switch operator at the master NCC.
Solid Yellow
An operator test is in progress (that is, a test
signal is currently being applied to the circuit by
the CSU).
Solid Red
Any alarm.
Flashing Yellow and Red
Errors received during user initiated test.
Flashing Red
Power-up self test failure.
Not Lit
No power, blown fuse.
If an alarm state is caused by exceeding the performance monitoring
threshold, the alarm does not clear until the error in the selected intervals
falls below the threshold. This will be equal to one or more 15 minute
intervals.
Decoding the NCC 2020 Network (NET) LED Indicator LED
The NET (network) LED is a tri-state indicator with six states, as follows:
Solid Green
A normal signal is being received from the
network (all OK).
Solid Yellow
NCC is looped toward network via a line
loopback (LLB) or payload loopback (PLB) and
no errors received from the network.
Solid Red
Continuous errors on the network (for example,
LOS, LOF, RAI, AIS).
NOTE
NOTE