Dual-line and multiline shelves, Dual-line and multiline shelves -2, System overview – Verilink Red Zone Encryption (REMS) (880-502423-001) Product Manual User Manual
Page 22

System Overview
2-2
Red Zone Encryption Management System (REMS) User Manual
Figure 2-1
Front Module Mating with Rear Connector Module in a Dual-line Shelf Configuration
First, the rear connector modules are installed from the back the shelf into
the individual slots. Then the front modules are plugged in from the front.
In doing so, the rear-facing connectors of the front module plugs into the
mating connectors of the shelf backplane and the rear connector module.
The backplane connector and the rear connector module mating
connectors are offset from each other.
Dual-line and
multiline shelves
The REMS plug-in front/back module assembly is installed in a standard
AS2000 dual-line or multiline shelf. Both the dual-line and multiline
shelves are mountable in a standard 19-inch rack. See Figur e2-2, Front
Panel View Concept Drawing, Dual-line and Multiline Shelf Rack
Configurations.
Figure 2-2
Front Panel View Concept Drawing, Dual-line and Multiline Shelf Rack Configurations
128-pin mating
Rear Connector
Front module
Module
Connectors
96-pin for mating with
shelf backplane connector
Notes: Modules are shown without dual-line shelf but in the horizontal plane necessary for a dual-line configuration.
Rear connector module is installed into the shelf first. Then, the front module is plugged in from the front.
Backplane connector is
offset toward the front of
the shelf relative to
the plane of the rear
connector module.
Dual-line shelf with split module assembly installed.
Concept of multiline shelf
SAR
PHY
1
DCE
SY
S
TRUNKLOCA
DS
3
SY
S
2172
2171
SNMP