Diagnostics, Diagnostics menu, Accessing the menu – Verilink QUAD DATA (880-503319-001) Product Manual User Manual
Page 35: Diagnostics menu -1, Accessing the menu -1, Chapter

Verilink QUAD DATA User Manual
4-1
Chapter
4
Diagnostics
This chapter covers the use of the Diagnostics Menu and the
Alarm Menu. Diagnostics are used to test and verify the QUAD
DATA module and associated network circuits. The Alarm Menu is
used to enable and configure alarm reporting.
Diagnostics Menu
Diagnostics are used to initiate or terminate loopbacks and test
patterns for testing and troubleshooting.
Accessing the
Menu
To access the Diagnostics Menu for the QUAD DATA module, first
select the module, (see
in Chapter 3).
Once the QUAD DATA module has been selected, use the D
command to access the Diagnostics Menu. See
.
Figure 4-1 QUAD DATA Diagnostics Menu
-- QUAD DATA DIAGNOSTICS MENU --
-- QUAD DATA DIAGNOSTICS MENU --
-- QUAD DATA DIAGNOSTICS MENU --
-- QUAD DATA DIAGNOSTICS MENU --
Port 1 Port 2 Port 3 Port 4
Port 1 Port 2 Port 3 Port 4
Port 1 Port 2 Port 3 Port 4
Port 1 Port 2 Port 3 Port 4
Interface type V.35 EIA-530 RS-449 X.21
Interface type V.35 EIA-530 RS-449 X.21
Interface type V.35 EIA-530 RS-449 X.21
Interface type V.35 EIA-530 RS-449 X.21
DPL loopback yes no no no
DPL loopback yes no no no
DPL loopback yes no no no
DPL loopback yes no no no
Far-end loopback no no no no
Far-end loopback no no no no
Far-end loopback no no no no
Far-end loopback no no no no
Test pattern none none none none
Test pattern none none none none
Test pattern none none none none
Test pattern none none none none
Pattern sync --- --- --- ---
Pattern sync --- --- --- ---
Pattern sync --- --- --- ---
Pattern sync --- --- --- ---
Test error counter 30402 0 0 0
Test error counter 30402 0 0 0
Test error counter 30402 0 0 0
Test error counter 30402 0 0 0
LOS detected no yes no no
LOS detected no yes no no
LOS detected no yes no no
LOS detected no yes no no
DTR (C) off <- off <- on -> off <-
DTR (C) off <- off <- on -> off <-
DTR (C) off <- off <- on -> off <-
DTR (C) off <- off <- on -> off <-
DSR (I) off -> on -> off <- off ->
DSR (I) off -> on -> off <- off ->
DSR (I) off -> on -> off <- off ->
DSR (I) off -> on -> off <- off ->
RTS off <- off <- off -> ---
RTS off <- off <- off -> ---
RTS off <- off <- off -> ---
RTS off <- off <- off -> ---
CTS off -> on -> off <- ---
CTS off -> on -> off <- ---
CTS off -> on -> off <- ---
CTS off -> on -> off <- ---
DCD on -> on -> off <- ---
DCD on -> on -> off <- ---
DCD on -> on -> off <- ---
DCD on -> on -> off <- ---
LL off <- off <- off -> ---
LL off <- off <- off -> ---
LL off <- off <- off -> ---
LL off <- off <- off -> ---
RL off <- off <- off -> ---
RL off <- off <- off -> ---
RL off <- off <- off -> ---
RL off <- off <- off -> ---
TM on -> on -> off <- ---
TM on -> on -> off <- ---
TM on -> on -> off <- ---
TM on -> on -> off <- ---
Dn) data port loop Tn) test pattern In) insert bit error
Dn) data port loop Tn) test pattern In) insert bit error
Dn) data port loop Tn) test pattern In) insert bit error
Dn) data port loop Tn) test pattern In) insert bit error
Fn) send FT1 code En) reset test counter X) exit this menu
Fn) send FT1 code En) reset test counter X) exit this menu
Fn) send FT1 code En) reset test counter X) exit this menu
Fn) send FT1 code En) reset test counter X) exit this menu
A [0.0.0.4] [0,4] QUAD DATA >
A [0.0.0.4] [0,4] QUAD DATA >
A [0.0.0.4] [0,4] QUAD DATA >
A [0.0.0.4] [0,4] QUAD DATA >