Tubetrace, Tubing bundles, Installation procedures – Thermon TubeTrace Tubing Bundles User Manual
Page 4: Bending procedure, Typical cems installation

3
Bending Procedure . . .
Thermon tubing bundles should be installed so there is
no strain on any fi ttings after the installation is complete.
The cross-sectional area of the tubing bundle should not
be fl attened, kinked or wrinkled. Refer to Table 1 for the
minimum acceptable bend radius for each type of Thermon
tubing bundle. Use a properly sized Thermon mechanical
tubing bender to assure constant radius bends where
possible. For bend radius greater than 254mm, use wooden
reel or spool as shown below.
Table 1: Bend Radius
Nominal
Bundle O.D.
mm
Minimum
Bend Radius
mm
Nominal
Weight
kg/m
Electrical Traced Bundles
33
152
2.3
36
178
3.6
38
178
4.3
43
203
5.0
46
228
5.8
48
254
6.5
53
279
6.9
56
305
7.2
58
305
7.9
76
406
12.6
89
508
15.1
79
406
13.3
Steam Traced Bundles
38
178
3.6
41
178
4.3
43
178
4.3
46
203
5.0
48
228
5.8
51
279
6.5
53
279
5.8
The Cross-Sectional Area of TubeTrace Tubing Bundle
Should Not Be Flattened, Kinked or Wrinkled.
OK
Typical CEMS Installation
Slope
Mechanical
Tube Bender
Tubing Bundle
Wooden Reel
or Spool
TubeTrace
®
Tubing Bundles
INSTALLATION PROCEDURES