background image

TASCAM LA-40MKIII

7

2–Names and Functions of Parts

Bottom panel

y

INPUT LEVEL switches 1–4

Switches that set whether the signal levels intput

to the

INPUTS

8 are +4 dBu (1.23 V) or -20 dBu

(0.0775 V). This setting can be made for each

channel independently.

u

OUTPUT LEVEL switches 5–8

Switches that set whether the signal levels output

from the

OUTPUTS

7 are +4 dBu (1.23 V) or -20

dBu (0.0775 V). This setting can be made for each

channel independently.

i

INPUT LINK switches 2–4

These switches allow an input signal to be routed

to any higher numbered output from 2–4. Two

or more inputs can also be assigned to multiple

outputs in sequence (see “3–ADA Functions” for

examples.)

o

INPUT LINK switches 6–8

These switches allow an input signal to be routed

to any higher numbered output from 6–8. Two

or more inputs can also be assigned to multiple

outputs in sequence (see “3–ADA Functions” for

examples.)

r

Power outlet (see NOTE below)

Use this three-prong outlet, which is not affected

by the power switch, to connect AC equipment

with a maximum power consumption of 400 W

(or 3A). This connector is convenient when using

multiple LA-40

MK

III units. The specifications are

displayed on the top of the unit.

NOTE

The EUR model does not have this power outlet, so the

panel here is blank.

t

AC IN connector

Connect the included power cord.

E_LA-40mkIII-OM_RevC.indd 7

08.12.19 1:03:23 PM