Confi guration—restore factory defaults – Studio Technologies 76B 2008 User Manual
Page 30

Issue 1, July 2008
Model 76B/77B User Guide
Page 30
Studio Technologies, Inc.
for Surround
Press and hold both the Dialnorm Enable and Dim buttons for 5 seconds
to restore Model 77B factory defaults. Once defaults have been restored,
the associated LEDs will light. After the buttons are released, confi gura-
tion mode will be exited and normal operation will resume.
Confi guration—Restore Factory Defaults
Factory Defaults: Device
address
A1.
+4.0 dBu auxiliary output nominal level.
–20.0 dBFS digital input reference level.
+4.0 dBu monitor output nominal level.
Surround input A assigned to input 1.
Surround input B assigned to input 2.
No input assigned to input 3 (disabled).
Stereo input A assigned to input 4.
Stereo input B assigned to input 5.
Stereo input C assigned to input 6.
Reference level set for fully attenuated (minimum) monitor output level.
Attenuation display mode selected.
85.0 dB SPL reference level.
–31 dB dialnorm reference level.
Dialnorm data assigned to surround input A.
–20.0 dB dim level.
Remote mute all disabled.
Remote dim disabled.
Remote auxiliary output on/off disabled.
6.0 dB channel pop solo up offset level.
–6.0 dB channel pop solo down offset level.
Warning:
Each Model 77B unit must have a unique address. Restoring factory defaults will reset only this
specifi c Model 77B to address A1. If another connected unit is already confi gured for address A1,
normal system operation will stop.
Note:
The 5-second delay is a safety feature ensuring that the factory defaults will not be accidently restored.