by pressing the Model 77B button labeled 
Reference Level. Setting the reference 
level is very simple but care is required:
1. Set up a precision sound pressure
level (SPL) measuring device at the 
desired listening location.
2. Place the StudioComm system in the
normal operating mode, not the con-
fi guration mode. Be certain that the 
dim, mute all, reference level, dialnorm 
enable, and downmix functions are not 
active. The remote mute all or remote 
dim functions must not be active.
3. Use the Model 77B Control Console
to select the input source that contains 
the desired reference signal source, 
e.g., pink noise.
4. Observing the SPL meter, adjust the
Model 77B’s rotary level control until 
the desired reference monitor system 
level has been reached.
5. Being careful not to disturb the posi-
tion of the rotary level control, enter the 
confi guration mode by pressing and 
holding the confi guration button locat-
ed on the Model 77B’s back panel.
6. Once the confi guration mode has been
entered, the monitor outputs will mute. 
Press and hold the reference level 
button; its associated LED will begin 
to fl ash. After fi ve seconds the LED 
will light steadily to indicate that a 
“snapshot” of the new reference level 
has been taken. The Model 77B’s nu-
meric display will then show the value 
of the new reference level. The value 
shown will always be a negative num-
ber as it’s always a value less than the 
maximum output level. The reference 
level button can now be released.
7. To complete the process the confi gura-
tion mode must be exited. This is per-
formed by again pressing and holding 
the confi gure button for two seconds. 
The new reference level is now stored 
in the Model 76B’s nonvolatile memory. 
Only by repeating the entire procedure 
can the value be changed.
Once the confi guration mode has been 
exited, the monitor outputs will again be-
come active. Confi rm that the correct level 
has been stored by pressing the reference 
level button. The SPL meter should display 
the desired level. If not, repeat the calibra-
tion procedure to achieve the desired goal.
You might wonder why you have to press 
and hold the reference level button for 
fi ve seconds before the selected value is 
recognized. This is provided specifi cally so 
that unauthorized users won’t accidentally 
change the reference level while they ex-
periment with the confi guration mode. Only 
if you know the “secret” will you be able to 
store a new value.
Overall Display Mode
The Model 77B’s 4-digit numeric display 
can be confi gured to display the output 
level in either an attenuation mode or an 
SPL mode. In the attenuation mode the 
output level is shown as a reduction in 
value relative to the maximum output level. 
When the rotary control is used to set the 
output level to its maximum the display will 
show 0.0. As the rotary control is moved in 
the counterclockwise direction the display 
will show negative values, reaching ap-
proximately –69.5 dB before the full mute 
function automatically mutes the outputs.
In the SPL mode the display can be 
confi gured to allow the output level to be 
presented to users in terms of the actual 