Studio Technologies 76B 2008 User Manual
Page 22

Issue 1, July 2008
Model 76B/77B User Guide
Page 22
Studio Technologies, Inc.
for Surround
Confi guration—Model 77B Device Address and Auxiliary Output
Nominal Level
Press and hold the Auxiliary Output Enable button to
display and select the Model 77B’s device address
and auxiliary output nominal level.
Default:
Device address A1.
+4.0 dBu auxiliary output nominal level.
Note:
The Model 77B’s device address is the only parameter stored in the Model 77B. All other parameters are
stored in the Model 76B.
When the Auxiliary Output Enable button is pressed, use the
input buttons to select the nominal level of the auxiliary output.
When LED Group 1-3 is lit the output level is +4.0 dBu. When
LED 1/4 is lit the output level is 0.0 dBu. When LED 2/5 is lit the
output level is –6.0 dBu. When LED 3/6 is lit the output level is
–12.0 dBu.
Use the level control to change this specifi c
Model 77B’s device address. Address can
be either A1, A2, A3, or A4.