Ac mains power – Studio Technologies 76B 2008 User Manual
Page 13

Model 76B/77B User Guide
Issue 1, July 2008
Studio Technologies, Inc.
Page 13
for Surround
The Model 77B requires a minimum of 
9 volts DC, 100 milliamperes maximum 
for correct operation. (The voltage must be 
measured directly at the Model 77B’s 9-pin 
connector.) So the maximum interconnect-
ing cable length is directly related to the 
resistive voltage losses associated with 
the two DC-carrying conductors. As the 
Model 76B supplies 12 volts and the Model 
77B requires 9 volts minimum, this directly 
leads to a 3 volt DC maximum drop due 
to the interconnecting cable. Using Ohm’s 
law it’s quite easy to determine whether 
the selected cable will support the desired 
interconnection length. Calculate the volt-
age drop by multiplying the total resistance 
(in ohms) of the proposed cable by 0.01 
(the square of the Model 77B’s maximum 
required current). Remember to include 
the resistance in both the DC+ and DC– 
wires in the fi gure for the total resistance.
AC Mains Power
The Model 76B is internally confi gured 
to operate from nominal 100, 120, or 
220/240 volts, 50/60 Hz. Units shipped 
to North America are factory selected for 
120 volt operation. Units bound for Japan 
are generally selected for 100 volts while 
our friends “down under” and in Europe 
receive units set for 220/240 volts. Before 
connecting the Model 76B to AC mains 
power, check to be certain that it is con-
fi gured to match the local mains voltage. 
Look on the back panel (adjacent to the 
power entry connector) for an indication 
of the factory-confi gured voltage. Note 
that an incorrect confi guration could pre-
vent operation or cause damage to the 
unit. Should it be necessary to change 
the unit’s operating voltage it must be 
performed only at the factory, or by a 
factory-authorized service technician.
The Model 76B uses an IEC-standard C14 
inlet connector to mate with the AC mains 
cord. The AC mains cord should have a 
C13 socket affi xed with the wire colors 
conforming to the internationally recog-
nized CEE color code:
Connection Wire
Color
Neutral (N)
Light Blue
Line (L)
Brown
Protective Earth (E) Green/Yellow
Safety Warning: The Model 76B does 
not contain an AC mains disconnect 
switch. As such, the AC mains cord 
plug serves as the disconnection 
device. Safety considerations require 
that the plug and associated outlet be 
easily accessible to allow rapid discon-
nection of AC mains power should it 
prove necessary.
As soon as AC mains power is applied, 
the Model 76B Central Controller’s power 
LED will light steadily. The two data activity 
LEDs, control console and metadata, may 
also light. Each of the connected Model 
77B Control Consoles will go through a 
power-up sequence, lighting each LED in 
Signal
Pin
Direction
Data+
1
To/From Model 77B
Data–
6
To/From Model 77B
Data Shield
2
To/From Model 77B
DC+
4
To Model 77B
DC–
9
To Model 77B
DC Power Shield
5
To/From Model 77B
Note: Connector type on Model 76B is 9-pin D-subminiature 
 
female. Connector uses 4-40 threaded inserts for
locking with mating plug.
Figure 6. Connections between Model 76B and 
Model 77B