Appendix a—connection pin out charts – Studio Technologies 76B 2012 User Manual
Page 42

Issue 3, August 2012
Model 76B/77B User Guide
Page 42
Studio Technologies, Inc.
for Surround
Appendix A—Connection Pin Out
Charts
Signal
Signal
Connections
High (+)
Low (–)
Shield
L
24
12
25
R
10
23
11
C
21
9
22
LFE
7
20
8
LS
18
6
19
RS
4
17
5
Auxiliary L
15
3
16
Auxiliary R
1
14
2
Notes: 1) All signals transformer-coupled digital audio;
selectable for AES3 or AES3id compatibility.
2) Connector type on Model 76B is 25-pin
D-subminiature female (DB-25F). Installer must provide
male (DB-25M). Connector uses 4-40 threaded inserts
for locking with mating plug.
3) Wiring scheme follows TASCAM DA-88 convention.
Standard DA-88-type wiring harnesses are directly
compatible, with the exception of 4-40 screw threads
being required.
Connections for Surround and Auxiliary Monitor
Outputs
Signal
Pin
Direction
RS-485 Data +
7
Input
RS-485 Data –
2
Input
Data Shield
1
Shield
Remote Mute All
5
Input
Remote Dim
6
Input
Remote Aux Monitor Out On/Off
8
Input
Remote Spare
9
Input
Remote Input Common
4
Common
Note: Connector type on Model 76B is 9-pin D-subminiature
female (DE-9F) Connector uses 4-40 threaded inserts
for locking with mating plug.
Connector Pin Outs for Metadata and Remote
Control Inputs
Signal
Pin
Direction
Data +
1
To/From Model 77B
Data –
6
To/From Model 77B
Data Shield
2
To/From Model 77B
DC +
4
To Model 77B
DC –
9
To Model 77B
DC Power Shield
5
To/From Model 77B
Note: Connector type on Model 76B is 9-pin D-subminiature
female (DE-9F). Connector uses 4-40 threaded inserts
for locking with mating plug.
Connections between Model 76B and Model 77B