beautypg.com

Studio Technologies 76B 2012 User Manual

Page 26

background image

Issue 3, August 2012

Model 76B/77B User Guide

Page 26

Studio Technologies, Inc.

for Surround

Configuration—Overall Display Mode and Reference Level
in dB SPL

Default: Attenuation display mode selected.

85.0 dB SPL reference level.

When the Display Mode button is pressed, use the Channel
Solo L and R buttons to select the overall display mode.
L LED lit means attenuation mode is selected; R LED lit
means SPL mode is selected. Use the buttons to change
the configuration.

Press and hold
the Display
Mode button
to display and
set the overall
display mode
and the SPL
reference level.

When the Display Mode button is
pressed, use the level control to
adjust the SPL reference level.
The range is 70.0 to 100.0 dB in
1.0-dB steps.