Page 15
for Surround
information prior to creating the intercon-
nection scheme to be used for installing 
multiple Model 77B units.
Configuration
After the physical installation has been 
completed it’s important that the system’s 
configuration options be carefully reviewed. 
In most cases one or more of the operating 
parameters will need to be revised to meet 
the needs of a specific installation. Many 
of the parameters will impact the signal 
flow in to and out of the Model 76B Central 
Controller. Other parameters affect how the 
one or more Model 77B Control Consoles 
will display status conditions and respond 
to user commands.
Configurable Parameters
Many StudioComm functions can be 
configured to meet the exact needs of 
an installation. The Model 77B Control 
Console is used to display and select the 
desired system configuration. Here’s an 
overview of what can be configured:
• Model 77B Device Address
• Auxiliary Monitor Output Nominal Level
• Digital Input Reference Level
• Monitor Output Nominal Level
• Input Select Buttons
• Reference Level
• Overall Display Mode
• Reference Level in dB SPL
• Dialnorm Reference Level
• Dialnorm Data to Surround Input
Assignment
• Dim Level
• Remote Inputs
• Channel Pop Solo Mode Offset Levels
The configuration diagrams, located at 
the end of this section, give details on set-
ting each parameter. An overview of each 
configurable parameter is provided in the 
following paragraphs.
Entering and Exiting the 
Configuration Mode
A small button is located on the back of 
each Model 77B Control Console, adjacent 
to the 9-pin D-sub connector. On any con-
nected Model 77B pressing and holding 
this button for two seconds places both the 
Model 76B and all the connected Model 
77B units into the configuration mode. The 
Model 76B will immediately mute the moni-
tor outputs as a protection measure. In the 
configuration mode the Model 77B’s array 
of buttons and LEDs no longer perform their 
normal functions, instead allowing you to 
observe and change many of the operating 
parameters. The dialnorm and output level 
LEDs, associated with the display mode 
section, will light alternately to indicate that 
the configuration mode is active.
To leave the configuration mode and return 
the Model 77B units to normal operation 
once again press and hold the configure 
button for two seconds. Note that configu-
ration changes are stored in nonvolatile 
memory only after the configuration mode 
has been exited.
Our apologies to those of you who find 
the configure button a pain to use, but it’s 
supposed to be that way! Seriously, the top 
of the button is slightly recessed from the 
back panel, making it harder to accidentally 
activate. We didn’t want normal operation to 
cease because someone pushed a Model 