Press and hold both the Dialnorm Enable and Dim buttons for 5 seconds
to restore Model 77B factory defaults. Once defaults have been restored,
the associated LEDs will light. After the buttons are released, configura-
tion mode will be exited and normal operation will resume.
Configuration—Restore Factory Defaults
Factory Defaults:
Device address A1.
+4.0 dBu auxiliary monitor output nominal level.
–20.0 dBFS digital input reference level.
+4.0 dBu monitor output nominal level.
Surround input A assigned to input 1.
Surround input B assigned to input 2.
No input assigned to input 3 (disabled).
Stereo input A assigned to input 4.
Stereo input B assigned to input 5.
Stereo input C assigned to input 6.
Reference level set for –60.0 dB monitor output level.
Warning: Each Model 77B unit must have a unique address. Restoring factory defaults will reset only this specific
Model 77B to address A1. If another connected unit is already configured for address A1, normal system
operation will stop.
Note:
The 5-second button-press delay is a safety feature ensuring that the factory defaults will not be accidently
restored.
Attenuation display mode selected.
85.0 dB SPL reference level.
–31 dB dialnorm reference level.
Dialnorm data assigned to surround input A.
–20.0 dB dim level.
Remote mute all disabled.
Remote dim disabled.
Remote auxiliary monitor output on/off disabled.
6.0 dB channel pop solo up offset level.