Overall display mode – Studio Technologies 76B 2012 User Manual
Page 18

Issue 3, August 2012
Model 76B/77B User Guide
Page 18
Studio Technologies, Inc.
for Surround
2. Place the StudioComm system in the
normal operating mode, not the con-
figuration mode. Be certain that the 
dim, mute all, reference level, dialnorm 
enable, and downmix functions are not 
active. The remote mute all or remote 
dim functions must not be active.
3. Use the Model 77B Control Console
to select the input source that contains 
the desired reference signal source, 
e.g., pink noise.
4. Observing the SPL meter, adjust the
Model 77B’s rotary level control until 
the desired reference monitor system 
level has been reached.
5. Being careful not to disturb the posi-
tion of the rotary level control, enter the 
configuration mode by pressing and 
holding the configuration button locat-
ed on the Model 77B’s back panel.
6. Once the configuration mode has been
entered, the monitor outputs will mute. 
Press and hold the reference level 
button; its associated LED will begin 
to flash. After five seconds the LED 
will light steadily to indicate that a 
“snapshot” of the new reference level 
has been taken. The Model 77B’s nu-
meric display will then show the value 
of the new reference level. The value 
shown will always be a negative num-
ber as it’s always a value less than the 
maximum output level. The reference 
level button can now be released.
7. To complete the process the configura-
tion mode must be exited. This is per-
formed by again pressing and holding 
the configure button for two seconds. 
The new reference level is now stored 
in the Model 76B’s nonvolatile memory. 
Only by repeating the entire procedure 
can the value be changed.
Once the configuration mode has been 
exited, the monitor outputs will again be-
come active. Confirm that the correct level 
has been stored by pressing the reference 
level button. The SPL meter should display 
the desired level. If not, repeat the calibra-
tion procedure to achieve the desired goal.
You might wonder why you have to press 
and hold the reference level button for 
five seconds before the selected value is 
recognized. This is provided specifically 
so that unauthorized users won’t acciden-
tally change the reference level while they 
experiment with the configuration mode. 
Only if you know the “secret” will you be 
able to store a new value.
Overall Display Mode
The Model 77B’s 4-digit numeric display 
can be configured to display the output 
level in either an attenuation mode or an 
SPL mode. In the attenuation mode the 
output level is shown as a reduction in value 
relative to the maximum output level. When 
the rotary control is used to set the output 
level to its maximum the display will show 
0.0. As the rotary control is moved in the 
counterclockwise direction the display will 
show negative values, reaching approxi-
mately –69.5 dB before the full mute func-
tion automatically mutes the outputs.
In the SPL mode the display can be 
configured to allow the output level to be 
presented to users in terms of the actual 
sound pressure level (SPL). Used in con-
junction with the reference level in dB SPL 
configuration and the stored reference level, 
SPL mode allows a user to see a visual rep-
resentation of the SPL level that is present 
in the listening environment. While it takes 
a little more care to correctly implement the 
SPL display mode, it can offer an enhanced 
experience for StudioComm users.