beautypg.com

Studio Technologies 76B 2012 User Manual

Page 23

background image

Model 76B/77B User Guide

Issue 3, August 2012

Studio Technologies, Inc.

Page 23

for Surround

Configuration—Digital Input Reference Level and Monitor
Output Nominal Level

Default: –20.0 dBFS digital input reference level.

+4.0 dBu monitor output nominal level.

Press and hold the Mute All button to display
and select the digital input reference level
and monitor output nominal levels.

When the Mute All button is pressed, use
the Channel Solo L and R buttons to select
the monitor output nominal level. Use the
buttons to change the configuration. L LED
lit means nominal level is 0.0 dBu; R LED lit
means nominal level is +4.0 dBu.

When the Mute All button is pressed, use the level
control to adjust the digital input reference level.
Available digital input reference levels are –20.0
dBFS, –18.0 dBFS, –16.0 dBFS, and –14.0 dBFS.

This manual is related to the following products: