for Surround

Configuration—Dialnorm Reference Level and Dialnorm Data
to Surround Input Assignment

Default: –31 dB dialnorm reference level.

Dialnorm data assigned to surround input A.

Press and hold the Dialnorm
Enable button to display and set
the dialnorm reference level and
assign the dialnorm data.

When the Dialnorm Enable button is
pressed, use the level control to adjust
the dialnorm reference level. The
range is –31 to –1 dB in 1-dB steps.

When the Dialnorm Enable button is pressed, use the Downmix 5.1 to Stereo and Stereo
to Mono buttons to assign the dialnorm data to the appropriate surround input. LED
5.1 to Stereo lit means dialnorm data assigned to surround input A. LED Stereo to Mono
lit means dialnorm data assigned to surround input B.