Remote control inputs, Connecting the model 76b to the model 77b – Studio Technologies 76B 2012 User Manual
Page 12

Issue 3, August 2012
Model 76B/77B User Guide
Page 12
Studio Technologies, Inc.
for Surround
or oscilloscope to confirm that the metada-
ta source is actually on the expected pins 
of the source connector prior to connecting 
it to the Model 76B.
Remote Control Inputs
Support is provided for three remote 
control input functions: remote mute all, 
remote dim, and remote auxiliary monitor 
output on/off. The inputs use logic gates, 
“pulled up” to +5 volts DC by way of resis-
tors, which are active whenever they are 
brought to their logic low state. Inputs of 
this type are commonly referred to as GPI 
inputs. While the input circuitry is protected 
from over-current and static (ESD) dis-
charge, care should be taken to prevent 
nasty signals from reaching them. The 
inputs are active only when held in the low 
state; they can’t be configured to change 
state (“latch”) in response to a logic pulse.
The same 9-pin D-subminiature connector 
used for the metadata input is also used 
for the remote control inputs. Refer to 
Figure 5 for the exact connection details. 
Note that pin 4 (remote input common) 
connects to the Model 76B’s internal circuit 
common connection as well as the Model 
76B’s chassis and mains earth connec-
tions. Figure 5 also shows one spare 
remote control input (pin 9). This is pro-
vided for future applications and should 
remain unconnected.
Connecting the Model 76B 
to the Model 77B
A 9-pin female D-subminiature connector, 
labeled To/From Control Console, is pro-
vided on the back panel of the Model 76B 
Central Controller. This is used to interface 
the unit with Model 77B Control Consoles. 
A 9-pin female D-sub connector, labeled 
To/From Central Controller, is provided 
on the back panel of each Model 77B 
Control Console. A cable with 9-pin male 
D-sub connectors on each end is used to 
interconnect the Model 76B with the Model 
77B units. A cable is included in the ship-
ping carton. The cable implements all nine 
connector pins in a one-to-one manner.
Should an interconnecting cable of a differ-
ent length be required there’s no problem 
for one to be fabricated and used. While it 
can be wired in a one-to-one fashion cov-
ering all nine pins, a minimum of only four 
connections are required: pin 1 (data +), 
in 6 (data –), pin 4 (DC +), and pin 9 (DC –). 
The Model 76B’s connector pin-out scheme 
was designed to allow creation of an inter-
connecting cable which uses commonly 
available 2-pair audio cable. This cable, 
consisting of two twisted pairs each with an 
individual shield, is typically sleek, flexible, 
and available in many colors. One pair and 
shield can be used for the data connections 
while the other pair and shield can be used 
for the DC connections. This implementation 
has the advantages of providing a shield 
for the data path and a more robust com-
mon connection (two conductors including 
the shield) for the DC power circuit. Refer to 
Figure 6 for details.
A few simple calculations are required to 
determine the maximum cable length when 
connecting a Model 77B to a Model 76B. 
The differential transmission scheme used 
by the system’s RS-485 interface makes 
an interconnection in excess of 1000 feet 
(300+ meters) easily possible. The limiting 
factor is typically the ability of the wiring to 
pass the DC power supplied by the Model 
76B to the Model 77B. The Model 76B sup-
plies 12 volt DC nominal with a maximum 
current of 200 milliamperes. 