Studio Technologies 55 2002 User Manual
Page 40

Issue 4, June 2002
Model 55/56 User Guide
Page 40
Studio Technologies, Inc.
Function: Set Dim Level
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
02H
Product ID (Model 55)
6
10H
Function: Set Dim Level
7
0nH
Status, Range 0-5:
0=full mute (approx. 70dB)
1=30dB dim
2=25dB dim
3=20dB dim
4=15dB dim
5=10dB dim
8
F7H
EOX, End of System Exclusive
Function: Control Room Mute
Byte
Value
Description
1
F0H
System-Exclusive Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
02H
Product ID (Model 55)
6
11H
Function: Control Room Mute
7
0nH
Status, Range 0-1, 0=No Mute, 1=Mute
8
F7H
EOX, End of System Exclusive