beautypg.com

Studio Technologies 55 2002 User Manual

Page 40

background image

Issue 4, June 2002

Model 55/56 User Guide

Page 40

Studio Technologies, Inc.

Function: Set Dim Level

Byte

Value

Description

1

F0H

System-Exclusive Message

2

00H

1st Byte of Studio Tech ID

3

00H

2nd Byte of Studio Tech ID

4

56H

3rd Byte of Studio Tech ID

5

02H

Product ID (Model 55)

6

10H

Function: Set Dim Level

7

0nH

Status, Range 0-5:
0=full mute (approx. 70dB)
1=30dB dim
2=25dB dim
3=20dB dim
4=15dB dim
5=10dB dim

8

F7H

EOX, End of System Exclusive

Function: Control Room Mute

Byte

Value

Description

1

F0H

System-Exclusive Message

2

00H

1st Byte of Studio Tech ID

3

00H

2nd Byte of Studio Tech ID

4

56H

3rd Byte of Studio Tech ID

5

02H

Product ID (Model 55)

6

11H

Function: Control Room Mute

7

0nH

Status, Range 0-1, 0=No Mute, 1=Mute

8

F7H

EOX, End of System Exclusive