Studio Technologies 55 2005 User Manual
Page 35

Model 55/56 User Guide
Issue 5, August 2005
Studio Technologies, Inc.
Page 35
Function: Set Dim Level
Byte Value Description
1 F0H
System-Exclusive
Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
02H
Product ID (Model 55)
6
10H
Function: Set Dim Level
7
0nH
Status, Range 0-5:
0=full mute (approx. 70 dB)
1=30
dB
dim
2=25
dB
dim
3=20
dB
dim
4=15
dB
dim
5=10
dB
dim
8
F7H
EOX, End of System Exclusive
Function: Control Room Mute
Byte Value Description
1 F0H
System-Exclusive
Message
2
00H
1st Byte of Studio Tech ID
3
00H
2nd Byte of Studio Tech ID
4
56H
3rd Byte of Studio Tech ID
5
02H
Product ID (Model 55)
6
11H
Function: Control Room Mute
7
0nH
Status, Range 0-1, 0=No Mute, 1=Mute
8
F7H
EOX, End of System Exclusive