beautypg.com

Studio Technologies 55 2005 User Manual

Page 35

background image

Model 55/56 User Guide

Issue 5, August 2005

Studio Technologies, Inc.

Page 35

Function: Set Dim Level

Byte Value Description
1 F0H

System-Exclusive

Message

2

00H

1st Byte of Studio Tech ID

3

00H

2nd Byte of Studio Tech ID

4

56H

3rd Byte of Studio Tech ID

5

02H

Product ID (Model 55)

6

10H

Function: Set Dim Level

7

0nH

Status, Range 0-5:

0=full mute (approx. 70 dB)

1=30

dB

dim

2=25

dB

dim

3=20

dB

dim

4=15

dB

dim

5=10

dB

dim

8

F7H

EOX, End of System Exclusive

Function: Control Room Mute

Byte Value Description
1 F0H

System-Exclusive

Message

2

00H

1st Byte of Studio Tech ID

3

00H

2nd Byte of Studio Tech ID

4

56H

3rd Byte of Studio Tech ID

5

02H

Product ID (Model 55)

6

11H

Function: Control Room Mute

7

0nH

Status, Range 0-1, 0=No Mute, 1=Mute

8

F7H

EOX, End of System Exclusive

This manual is related to the following products: