power to pins 2 and 3 of the 2-wire PL in-
tercom connectors. The Model 47 will also 
provide 200 ohm terminating impedances 
for both pins 2 and 3 of the party-line con-
nectors. The DC power and termination 
capabilities allow direct powering of dual-
channel intercom belt packs, such as the 
RTS BP325. In addition, listen-only belt 
packs, such as the Model 34 from Studio 
Technologies, Inc. can be directly con-
nected. There’s also no problem connect-
ing single-channel intercom belt packs or 
user stations.
2-Wire Nominal Audio Level
DIP switch 2 allows adjustment of the 
nominal audio level for the two 2-wire 
party-line channels associated with inter-
face 1. When the DIP switch is in its off 
(down) position the nominal level is 
–14 dBu. This level is compatible with 
intercom belt packs from manufacturers 
such as Clear-Com. When the DIP switch 
is in its on (up) position the nominal level 
is –10 dBu. This setting is appropriate 
when belt packs from RTS, such as the 
BP325, or listen-only talent amplifier units 
from Studio Technologies, Inc. are con-
nected. For best Model 47 performance 
it’s important that the 2-wire nominal level 
selection be made correctly.
4-Wire Nominal Audio Level
DIP switches 3 and 4 are used to config-
ure the nominal level of the input and out-
put circuitry associated with interface 1’s 
two 4-wire input and output connections. 
Four level settings are available: 0, +4, 
+6, and +8 dBu. Prior to setting these DIP 
switches it’s important to determine the 
nominal audio level of the equipment con-
nected to the Model 47’s 4-wire input and 
outputs. This may take a little investigation 
but is important for obtaining the best pos-
sible Model 47 performance.
The 0 dBu setting is provided specifically 
for use when a Model 47 is interconnected 
with a Clear-Com matrix intercom system. 
The +4 dBu setting is appropriate when 
standard audio lines with “+4” nominal 
levels are interconnected. The +6 dBu 
setting can be appropriate when intercon-
necting with equipment manufactured in 
Europe, such as the digital matrix intercom 
systems from Riedel. The +8 dBu setting 
is provided specifically when interconnect-
ing the Model 47 with audio signals asso-
ciated with an RTS ADAM-series of matrix 
intercom system. This includes the related 
RVON-I/O unit.
When DIP switches 3 and 4 are in their 
off (down) position the nominal level is 
set for 0 dBu. When DIP switch 3 is on 
(up) and DIP switch 4 is off (down) the 
nominal level is +4 dBu. When switch 
3 is off (down) and switch 4 is on (up) 
the nominal level is +6 dBu. When both 
switches 3 and 4 are in their on (up) posi-
tion the nominal level is configured for 
+8 dBu.
Advanced 
Configuration
Four DIP switches are provided on the 
Model 47’s back panel. They allow the 
two interfaces to be configured for sev-
eral advanced operating modes. Refer to 
Figure 6 for a detailed view of these DIP 
switches. The available configurations 
include auto terminate, auto null button, 
logic refresh, and factory test.