Operation, Power up – Studio Technologies 5152 V.2 User Manual
Page 21

Model 5152 User Guide
Issue 4, September 2013
Studio Technologies, Inc.
Page 21
Model 5152
Video Generator/Audio Embedder Module
second digit represents what is to happen 
to the audio associated with digital audio 
inputs 3 and 4. The digit 
N indicates that
the digital audio inputs are not to be 
embedded. The numbers 
1, 2, 3, and 4
represent the SDI group that the digital 
audio inputs are to be embedded into. 
Figure 9 shows 
EMBED=34 which indi-
cates that digital audio inputs 1 and 2 are 
to be embedded into SDI group 3 and 
digital audio inputs 3 and 4 are to be em-
bedded into SDI group 4. Another example 
would be EMBED=2N which would specify 
that digital audio inputs 1 and 2 are to be 
embedded into SDI group 2 while digital 
audio inputs 3 and 4 are not to be embed-
ded (inactive).
A special configuration selection is 
EMBED=NN. This configures the Model 
5152 to not embed any audio signals. In 
this situation any embedded audio as-
sociated with the connected SDI input will 
pass through the module. While this con-
figuration will typically not be used it can 
prove to be useful in certain situations. For 
example, it can be used during trouble-
shooting, disabling the Model 5152’s em-
bedding function and allowing an SDI input 
to pass through the module completely 
unchanged. Test signals can be confirmed 
as passing through the module correctly 
and terminating on a downstream piece of 
equipment. Turning off embedding can also 
be useful when, in a special application, all 
the audio groups associated with an SDI 
input need to remain embedded and pass 
through to the Model 5152’s SDI output.
GPI= selects the status of the GPI (gen-
eral-purpose input) function. 
DISABLED
selects that the function is not active. 
EMBEDOFF selects that the GPI can be 
used to control the on/off status of the 
Model 5152’s embedder function. The 
function is active low. When the GPI is not 
pulled low (switch or contact closure open 
(not shorted)) the embedder function is ac-
tive. When the GPI is low (switch or contact 
closure closed (shorted)) the embedder 
function is disabled. (Of course, if embed-
ding has been disabled in the configuration 
(EMBED=NN), the GPI function would not 
impact embedder operation.) Note that if 
the hardware version of this specific Model 
5152 does not support the GPI function 
this text line can be part of the file but will 
not be recognized.
GPO= selects the status of the GPO 
(general-purpose output) function. 
DISABLED selects the function to be not 
active. SDIVALID selects the GPO output 
to be high when a valid SDI signal is con-
nected to the selected SDI input (coaxial 
(BNC) or optical). SDINOTVALID selects 
the GPO output to be high when a valid 
SDI signal is not connected to the selected 
SDI input (coaxial (BNC) or optical); the 
GPO output will be low when a valid SDI 
signal is connected. Note that if the hard-
ware version of this specific Model 5152 
does not support the GPO function this 
text line can be part of the file but will 
not be recognized.
Operation
Power Up
Upon 12 volt DC power being applied to 
the Model 5152 the twelve front-panel 
LEDs will perform a “walk-through” test, 
with each LED lighting briefly in sequence. 
Then the LEDs will light in patterns that 
represent the version numbers of the 
firmware (embedded software) files that 