for Surround
Configuration—Sync Source, Sync Input Termination, Audio-
Synced-to-Video Sample Rate, and Digital Monitor Output Types
Default: Sync source is L/R of currently selected input.
Sync input terminated.
Audio-synced-to-video sample rate 48 kHz.
Pre-fader surround/stereo input C direct digital monitor output type AES3 (110 ohms/5 Vpp).
Post-fader surround/auxiliary stereo digital monitor output type AES3 (110 ohms/5 Vpp).
Press and hold the Mute All button
to display and select the sync
source, sync input termination,
audio-synced-to-video sample
rate, and digital monitor output types.
Use the Channel Solo C and LFE
buttons to select the pre-fader
surround/stereo input C direct
digital monitor output type. Use
the buttons to change the configu-
ration. C LED lit means AES3id
(75 ohms/1 Vpp); LFE LED lit
means AES (110 ohms/5 Vpp).
This LED displays the configuration of
the sync input termination. LED not lit
means sync input is not terminated; LED
lit means terminated with 75 ohms. Use
the button to change the configuration.
Use the Channel Solo LS and
RS buttons to select the post-
fader surround/auxiliary stereo
digital monitor output type. Use
the buttons to change the config-
uration. LS LED lit means AES3id
(75 ohms/1 Vpp); RS LED lit
means AES3 (110 ohms/5 Vpp).
Use these buttons to select sync source:
LED Group 1-3 lit means sync input, video
LED 1/4 lit means sync input, DARS
LED 2/5 lit means sync input, word clock
LED 3/6 lit means L/R of currently selected input
Use the level con-
trol to adjust the
audio-synced-
to-video sample
rate. Available
sample rates
are 32, 44.1, 48,
88.2, 96, 176.4,
and 192 kHz.