Studio Technologies 76DBA V.3.00 User Manual
Page 28

Issue 1, November 2010
Model 76DBA/77B User Guide
Page 28
Studio Technologies, Inc.
for Surround
Configuration—Model 77B Device Address, Stereo Input C
Sample Rate Converter, and Auxiliary Stereo Digital and Analog
Monitor Outputs Nominal Level
Press and hold the Auxiliary Output
Enable button to display and select the
Model 77B’s device address, stereo input
C sample rate converter, and auxiliary
stereo digital and analog monitor outputs
nominal level.
Default: Device address A1.
Stereo input C sample rate converter enabled.
0 dB auxiliary stereo digital and analog monitor outputs nominal level.
Note:
The Model 77B’s device address is the only parameter stored in the Model 77B. All other parameters are
stored in the Model 76DBA.
Use the input buttons to select the nominal level of the
auxiliary stereo digital and analog monitor outputs.
LED Group 1-3 lit means the output level is 0 dB;
LED 1/4 lit means the output level is –6 dB;
LED 2/5 lit means the output level is –12 dB;
LED 3/6 lit means the output level is –18 dB.
Use the level control to change this specific
Model 77B’s device address. Address can
be either A1, A2, A3, or A4.
This LED displays the configuration of the stereo
input C sample rate converter (SRC). LED not
lit means SRC is bypassed; LED lit means SRC
enabled. Use the button to change the configuration.