for Surround

Default: Reference level set for –60.0 dB post-fader monitor output level.

Note:

The 5-second button-press delay is a safety feature ensuring that the reference level will not be accidently

changed. To permanently store the new value, you must still exit the configuration mode.

Configuration—Reference Level

Press and hold the Reference Level button for 5 seconds to take a “snapshot”
of the level control’s setting at the time configuration mode was entered. The
Reference Level LED will flash when the button is initially pressed and then
light steadily when the “snapshot” has been taken.