Space Ray RSTP Series User Manual
Page 25

Form 43206000
-24-
Sept 2011
Flue vent termination
must be 1 ft. (30cm)
higher than combustion
air inlet cap
Perforated Cover
(Remove)
Control Box
The combustion air inlet should
be not less than 3 ft. (0.9m),
either vertically or horizontally,
from the flue vent termination.
Adapter Plate
Part #42783000
(Install)
End View
6 Starting Collar
(field supplied)
Flue Collar
Combustion Air Cap
(Leslie VersaCap
Type B)
6 Diameter
Single-Wall Pipe
Flashing
1/2 (12mm) fall per 20ft (6m)
toward vent terminal
Horizontal
Through Sidewall
6 (15cm)
Minimum
6 Starting Collar
(field supplied)
3 ft. (91cm)
Minimum
Vertical
Through the roof
Control Box
Perforated Cover
(Remove)
Adapter Plate
Part #42783000
(Install)
End View
Alternate Combustion
Air Intake Location