Cv 11 packet time out value – SoundTraxx DSD-150/DSX Technical Reference User Manual
Page 12

Address Mode
Direct Mode
Register Mode
Ops Mode Short Form
Paged Mode
Ops Mode Long Form
12
Digital Sound Decoder Technical Reference
CV 11
PACKET TIME OUT
VALUE
Description
Contains a value between 0 and 255 corresponding to the time period that is allowed to elapse
between receipt of a valid packet addressed to the DSD before a throttle shutdown occurs.
bit 7
bit 0
D7
D6
D5
D4
D3
D2
D1
D0
D0-D7:
Packet Time-out Value
The time out period is computed in seconds as:
Time Out Period = CV11 X 10
A CV value of 0 disables the time out period and the locomotive will run indefinitely without
receiving another packet.
For all other values, the DSD maintains an internal timer which is reset every time the DSD
receives a valid broadcast address packet or other valid packet whose address matches its
primary address or, if enabled, the extended address or consist address.
In the event no valid packets are received within the prescribed time period, the DSD will bring
the locomotive to a stop at the rate set by CV 4 and CV 24. The state of the auxiliary function
outputs will remain unchanged.
Default value:
00
❐
■
❐
❐
■
■