Error Messages
Full list of error messages:
•
Alarm type: This kind of message must be acknowledged by the user pressing any key
before any other command.
•
Message type: This type of message hasn't to be acknowledged. It's cleared as soon as the
problem which originated it is resolved.
Note: Don't take in account the messages which may appear in the first seconds after a reset.
Message displayed
Type
Meaning
AUDIO ROUTING ERROR
Alarm
Switching from a two tracks confi-guration
to four tracks or inversely, the previously
selected audio rou-ting is invalidated and
replaced by the default option, i.e. STEREO
in two tracks and FOUR TRACKS DIRECT
in four tracks.
Acknowledge the alarm and change the
audio routing if needed.
BAD EXT FREQ
Inactive message
BAD SYNC CHOICE
Message
There is an incompatibility between
Stelladat II's configuration at 96 kHz and an
external sync refe-rence at 44.1 kHz
(AES/EBU or wordclock).
Change Stelladat II's configuration.
BAT LO
Message
The battery has reached its minimal charge
level: replace it without delay
BATT NOT SELECTED
Message
If the recorder is powered with a battery its
recommended for a longer lasting of the
battery itself to inform Stelladat II of the
type of battery used, so that it can choose
the best adapted power mana-ging
program.
BLANK DETECTED
Alarm
This alarm informs that the tape section
after the current location is not format-ted.
(In BLANK SEARCH ON only)
DOWN 1 SELECTED
Alarm
By Stelladat II's power on only. Reminds
that the sampling frequency is altered
according to the needs of NTSC video.
END OF RECORD
Inactive message
END OF TAPE
Message
Self-explanatory.
EXTERN DC TOO HIGH
Message
The external powering voltage is higher
than the maximal allowed value.
EXT LO
Message
The external powering voltage is lower than