5.7 UNIT STATUS
This menu shows all the main current settings of the SX-R4 on 4 pages. The Joystick allows navigating
between the four pages.
POWER
Fuel gauge in [%] and as bar-graph
HD FREE
Remaining disk space on the hard disk
HD HH :MM
Remaining recording time on the hard disk in
hours and minutes. Depends of the current
configuration of the recorder.
CF FREE
Remaining disk space on the CF card if
inserted
CF HH :MM
Remaining recording time on the CF card
in hours and minutes. Depends of the
current configuration of the recorder.
SYNC
Audio
synchronisation
currently
used.
Following values might be displayed:
AES: at least one track is set to AES input. If
the Sync is not valid or incorrect, the AES
Alarm will flash.
INTERNAL: the internal generator is being
used.
WCK IN : the word clock input is used. If the
Sync is not valid or incorrect, the SYNC
Alarm will flash to warn.
VIDEO IN : the video input is used. If the
Sync is not valid or incorrect, the SYNC
Alarm will flash to warn.
FS
Sample frequency being currently used:
44.1k, 48k, 88.2k, 96k, 176.4k, 192k.
BITDEPTH
Numbers of bits per sample being currently
used: 24 bits, 16Dbits (dithering), 16 bits.
UP/DOWN
0.1% NTSC Correction of the sampling
frequency: NOMINAL, UP, DOWN.
WAV FILE
Format of the generated WAVE files :
MONO, STEREO, POLY
MIRROR
Mirroring status on the CF Card: OFF, ON.