2.4.2. re-setting the end limits
readjusting the upper end limit
1) Press the
Λ
button to bring the motorised
product to the end limit to be readjusted.
2) Press the
Λ
and
V
buttons at the same time
until the motorised product moves up and down.
3) Press the
Λ
or
V
button to move the motorised
product to the new desired position.
4) To confirm the new end limit, press the
my
button until the motorised product moves up and
down.
readjusting the lower end limit
1) Press the
V
button to bring the motorised
product to the end limit to be readjusted.
2) Press the
Λ
and
V
buttons at the same time
until the motorised product moves up and down.
3) Press the
Λ
or
V
button to move the motorised
product to the new desired position.
4) To confirm the new end limit, press the
my
button until the motorised product moves up and
down.
2.4.3. replacing a lost or broken somfy control point
Only switch off the power to the application to
be reset.
This reset deletes all the local control points,
however the sensors, end limit settings and
favourite position are retained.
1)
Position the motorised product at the mid-height
position.
2)
Cut the power supply for 2 seconds.
3)
Switch the power supply back on for 5 to 15
seconds.
4)
Cut the power supply for 2 seconds.
5)
Switch the power supply back on: the motorised
product moves for a few seconds. (If the applica-
tion is in the upper or lower limit position, it will
make a brief up and down movement).
6)
Press the PROG button on the new control point
until the motorised product moves up and down:
the new control point is programmed and all the
other control points are deleted.