Preinstallation, Clearances, Framing and finishing – Design Dynamics DVF-36S-N User Manual

Page 6: Continued

background image

www.desatech.com

120441-01A

6

CLEARANCES

Minimum clearances to combustibles for the
fireplace are as follows:
*Back and sides

0"

Perpendicular walls

6"

Floor

0"

Ceiling to louver opening

42"

Front

36"

Top of Standoffs

0"

Vent

(See venting instructions

for specific venting

clearances.)

Combustible material with a maximum thick-
ness of 5/8" may be flush with the top front
of fireplace.
* For back and sides of fireplace, do not pack
with insulation or other materials. 0" clear-
ance to combustible materials are for framing
purpose only.

NOTICE: This fireplace is intend-

ed for use as supplemental heat.

Use this fireplace along with

your primary heating system.

Do not install this fireplace as

your primary heat source. If you

have a central heating system,

you may run system’s circulat-

ing blower while using fireplace.

This will help circulate the heat

throughout the house.

FRAMING AND FINISHING

Figure 4 shows typical framing of this fireplace.
Figure 5 shows framing for corner installation.
All minimum clearances must be met.
If you are using a separate combustible man-
tel piece, refer to Figure 6 for proper instal-
lation height. You can install noncombustible
mantels at any height above the fireplace.
Note: Noncombustible mantels may discolor!

PreinStALLAtiOn

Continued

56

3

/

4

"

43

1

/

4

"

33"

28"

Figure 4 - Framing Clearances with

Outside Air Flex Duct

41

3

/

8

"

82

1

/

8

"

43

1

/

4

"

43"

19

9

/

16

"

58

1

/

4

"

Nailing
Tabs

Figure 5 - Framing Clearances for

Corner Installation

Figure 6 - Clearances for Combustible

Mantels

C

B

A

D

E

F

G

3

2

1

4
5
6

7

Wall

Ref.

Mantel

Depth Ref.

Mantel

from Top of

Opening

1

14"

A

16"

2

12"

B

14"

3

10"

C

12"

4

8"

D

10"

5

6"

E

8"

6

4"

F

6"

7

2"

G

4"