PARTS LIST FOR VENTING KITS
AND COMpONENTS

DESA (5"/8") Pipe & Vent Kits
Number Description
P58-6

6" Section Double Wall Pipe,

Galvanized

P58-12

12" Section Double Wall Pipe,

Galvanized

P58-24

24" Section Double Wall Pipe,

Galvanized

P58-36

36" Section Double Wall Pipe,

Galvanized

P58-48

48" Section Double Wall Pipe,

Galvanized

PA58-712 Adjustable 7"-12" Section Double

Wall Pipe, Galvanized

E58-45

45° Elbow, Galvanized

E58-90

90° Elbow, Galvanized

HTS-58

Horizontal Square Termination,

Galvanized

VT-58

Vertical Round Termination,

Galvanized

SC-58

Storm Collar, Galvanized

WF-58

Wall Firestop, Galvanized

RF-58-6 Roof Flashing - 0 to 6/12 Pitch,

Galvanized

RF-58-12 Roof Flashing - 6/12 to 12/12 Pitch,

Galvanized

VR-58

Vertical Restrictor, Galvanized

S-58

Vinyl Siding Standoff,

Galvanized

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

SF-58

Stucco Flashing -

For use with HTS-58

RF-58

Flat Roof Flashing

AK6-37

37" Outside Air Flex Vent Kit

AK6-75

75" Outside Air Flex Vent Kit

ventinG inStALLAtiOn

Continued

FirePLAce

inStALLAtiOn

CHECK GAS TYPE

Use proper gas type for the fireplace unit you
are installing. If you have conflicting gas types,
do not install fireplace. See retailer where you
purchased the fireplace for proper fireplace
according to your gas type.

INSTALLING GAS pIpING TO
FIREpLACE LOCATION

WARNING: A qualified

service person must connect

fireplace to gas supply. Follow

all local codes.

CAUTION: For propane/LP

units, never connect fireplace

directly to the propane/LP sup-

ply. This heater requires an ex-

ternal regulator (not supplied).

Install the external regulator

between the fireplace and pro-

pane/LP supply.

WARNING: For natural gas,

never connect fireplace to

private (non-utility) gas wells.

This gas is commonly known

as wellhead gas.

Installation Items Needed
Before installing fireplace, make sure you
have the items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
• approved flexible gas line with gas connec-

tor (if allowed by local codes)

* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable al-
ternative to test gauge connection. Purchase
the CSA design-certified equipment shutoff
valve from your retailer.