ventinG inStALLAtiOn

Continued

WARNING: Do not recess

vent termination into any wall.

This will cause a fire hazard.

5. Noncombustible Exterior Wall: Position

the horizontal vent cap in the center of the
8

1

/

2

" round hole and attach to the exterior

wall with four wood screws provided.
Before attaching the vent cap to exterior
wall, run a bead of non-hardening mastic
(pliable sealant) around the outside edges
to make a seal between it and the outside
wall. Note: The four wood screws provided
should be replaced with appropriate fas-
teners for stucco, brick, concrete or other
types of sidings (see Figure 10).

Combustible Exterior Wall: For vinyl
siding, stucco or wood exteriors, a siding
standoff may be installed between the
vent cap and exterior wall. The siding
standoff prevents excessive heat from
damaging the siding materials. Siding
material must be cut to accommodate
standoff. Bolt the vent cap to the stand-
off. Apply non-hardening mastic around
outside edge of standoff. Position the
standoff/cap assembly in the center of the
11

1

/

2

" square hole and attach to exterior

wall with wood screws provided (see Fig-
ure 11). The siding standoff must sit flush
against the exterior fascia material.

6. Combustible Exterior Wall Only: Slide

the wall firestop over the vent pipe before
connecting horizontal run to vent cap (see
Figure 12).

Figure 10 - Installing Horizontal Vent Cap

(Noncombustible Exterior)

Wood
Screw

Vent Cap

Figure 11 - Installing Siding Standoff

(Combustible Exterior Wall)

Cut Siding Away to
Fit Standoff

Wood
Screw

Screws

Standoff

Vent
Cap

Apply Mastic
to All Four Sides

Vent Cap
(Horizontal
Termination)

Interior Wall
Surface

Wall
Firestop

Horizontal
Vent Pipe

Figure 12 - Connecting Vent Cap with

Horizontal Vent Pipe

Screw

Apply
Mastic to All
Four Sides

7. Carefully move fireplace, with vent as-

sembly attached, toward wall and insert
vent pipe into horizontal termination. The
pipe overlap should be a minimum of 1

1

/

4

"

(see Figure 13, page 11).

8. Combustible Exterior Wall Only: Slide

wall firestop against interior wall surface
and attach with screws provided. See Fig-
ure 13, page 11, for horizontal termination
details.

9. Place fireplace into position and shim with

noncombustible material if needed. Nail or
screw side flanges to framing to secure
unit in place. IMPORTANT: Make sure fire-
place is level before securing. If fireplace
is not level it will not work properly.