SL Power Electronics OV-24 User Manual
Ov-12/24 series installation instructions
2311 STATHAM PKWY
OXNARD, CA 93033 + 805-486-4565
Internet: www.condorpower.com
VOLTAGE ADJUSTMENT RANGE: 6.2 – 33VDC
ADJUSTMENT PROCEDURE:
1.
REFER TO CHART 1 FOR SUGGESTED OVP TRIGGER VOLTAGES.
2.
CONNECT TEST CIRCUIT AS SHOWN IN FIGURE A. TEST VOLTAGE SOURCE MAY BE ANY
POWER SUPPLY WITH A SHORT CIRCUIT LIMIT OF LESS THAN 8 AMPS (OVP-12) OR 20 AMPS
(OVP-24).
3.
ENERGIZE AND ADJUST THE TEST VOLTAGE SOURCE TO THE DESIRED OVP VOLTAGE.
4.
ROTATE THE OVP ADJUSTMENT POT CCW (FROM ITS MAXIMUM CW POSITON) UNTIL THE OVP
FIRES AS INDICATED BY A BY A 1 VOLT READING ON M1. LEAVE THE POT IN THIS POSITION,
UNIT IS NOW READY FOR INSTALLATION INTO POWER SUPPLY.
5.
BOLT THE OVP ONTO THE POWER SUPPLY USING THE MOUNTING HOLES PROVIDE. CONNECT
THE WHITE (+) LEAD TO THE POSITIVE OUTPUT AND THE BLACK (-) LEAD TO THE NEGATIVE
OUTPUT.
CHART 1
FIGURE A
Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other
than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA,
EN, and IEC safety standards.
41-35625-0001 Rev. A 5/4/06
OV-12/24 SERIES
INSTALLATION INSTRUCTIONS
MODEL
INTERMITTENT
CONTINUOUS
OVP-12
12A
8A
OVP-24
30A
20A
POWER SUPPLY
OUTPUT VOLTAGE
SUGGESTED OVP
TRIGGER VOLTAGE
5 VDC
6.2+/-0.4V
6 VDC
7V
12 VDC
14V
15 VDC
17V
18 VDC
21V
20 VDC
23V
24 VDC
27V
DUAL +/-12 VDC
27V
DUAL +/- 15 VDC
33V
CURRENT +
LIMITED
POWER
SUPPLY
-
+
OVP-12
OR
OVP-24
-
M1