SL Power Electronics GPC140 User Manual
Gpc140 series installation instructions
SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
MODEL NUMBERS: GPC140-X, where X may be the number 5, 12, 15, 24 or 28. Models may be followed by suffixes: -
C, -T, -T1, -T2, -XXX and/or G. Suffix –C indicates cover is provided; -T indicates terminal block used on input and output
connectors; -T1 indicates terminal block used on input; -T2 indicates terminal block used on output; -XXX indicates value
added configurations that have no impact on safety which may be any number from 001 thru 999; and G indicates compliance
to RoHS.
RATINGS:
Input: 100-240 V ac, 4.0 A, 50/60 Hz
Outputs:
MAXIMUM OUTPUT AMPS AND WATTS
CONVECTION COOLING
FORCED AIR COOLING (1)
Model
Volts
Without Cover
With Cover
With & Without Cover
GPC140-5
5
26.0 A 130 W
24.0 A 120 W
30.0 A 160 W
GPC140-12
12
11.7 A 140 W
10.0 A 120 W
13.3 A 160 W
GPC140-15
15
9.3 A 140 W
8.0 A 120 W
10.7 A 160 W
GPC140-24
24
5.8 A 140 W
5.8 A 140 W
6.7 A 160 W
GPC140-28
28
5.0 A 140 W
5.0 A 140 W
5.7 A 160 W
Notes:
1.
Minimum airflow for forced air cooling is 26 cfm.
2.
Maximum ambient temperature for continuous output power specified above is 50 °C .
3.
Maximum Relative Humidity 96%, no condensation.
4.
Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION: SL Power Electronics Corp. declares under our sole responsibility that all models
listed above are in conformity with the applicable requirements of EN60950-1 following the provisions of the Low
Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable requirements of
UL 1950, CSA 22.2 No. 950 (Level 3), and EN60950-1 for Pollution Degree 2 environment and Class I TN-S power systems.
The output of these supplies meet the requirements for SELV and are not an energy hazard.
GROUNDING: Protection Class I requires that the chassis and/or J1-5/TB1-3 be bonded to Protective Earth in the end
application. Using J1-5/TB1-3 for the primary system earthing terminal is not recommended.
Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the applicable safety
standards, must be maintained after installation to preserve the intended safety.
The maximum operating temperatures of certain safety components, as defined in the applicable safety standards, must not be
exceeded after installation to preserve the intended safety. The output power, ambient air temperature and the availability,
amount, direction and/or restriction of airflow influence the temperatures of these components.
WARNING! RISK OF FIRE!
A blown fuse is an indication of catastrophic failure of circuit component(s). Repair must be performed by SL Power
Electronics Corp. authorized personnel. Fuse F1 must be replaced with UL Listed and CSA Certified type. Refer to fuse
marking on printed wiring board for value.
C O N N E C T I O N S
J1
TB1
AC INPUT
J2
SIGNAL OUTPUTS
J3
TB2 DC OUTPUTS
1
1
Line
1 Power Fail
1, 2, 3, 4
1, 2
+ Output
3
2
Neutral
2 - Sense
13, 14, 15, 16
7, 8
+ Output
5
3
Ground
3 + Sense
5, 6, 7, 8
3, 4
Return
4 N/C
9, 10, 11, 12
5, 6
Return
MATING CONNECTORS:
J1 Amp Housing 640250-5 Contact 770476-1
J2 Amp 640440-4
J3 Amp Housing 1-640250-6 Contact 770476-1
CAUTION: Do not exceed 5 A per pin on J3 or 15 A per terminal on TB2.
SL Power Electronics Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than
authorized agents of SL Power Electronics Corp., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, and IEC/EN
safety standards.
41-33339-0001 Rev. F 10/31/06
GPC140 SERIES
INSTALLATION INSTRUCTIONS
Attention, Consult
Accompanying Documents
Alternating Current
Attention, Dangerous Voltages
Earth (Ground)
EXPLANATION OF SYMBOLS
Direct Current