beautypg.com

SL Power Electronics GLM75 Multiple Output User Manual

SL Power Electronics Equipment

background image

CONDOR DC POWER SUPPLIES INC.
2311 STATHAM PKWY
OXNARD, CA 93033 + 805-486-4565

RATINGS:
Input: 100-240 V ac, 3.1 A, 50/60 Hz
Output: Maximum Continuous Power,

Standard & -L option

With Chassis/Cover

(Note 5)

total of all outputs at ambient of 50 °C.

26 CFM

0 CFM

26 CFM

0 CFM

110 Watts

75 Watts

110 Watts

65 Watts

Output #1

Output #2

Output #3

Output #4

MODEL

Note 2

Note 3

Note 2

Note 3

Note 2

Note 3

Note 2

Note 3

GLM75A

+5.1 V

8 A

10 A

+12 V

2.5 A

3.0 A

-12 V

1.0 A

1.0 A

+12 V 2.5 A

3.0 A

GLM75B

+5.1 V

8 A

10 A

+12 V

2.5 A

3.0 A

-5 V

1.0 A

1.0 A

+12 V 2.5 A

3.0 A

GLM75C

+5.1 V

8 A

10 A

+12 V

2.5 A

3.0 A

-15 V

1.0 A

1.0 A

+15 V 2.5 A

3.0 A

GLM75D

+5.1 V

8 A

10 A

+24 V

2.5 A

2.5 A

-12 V

1.0 A

1.0 A

+12 V 2.5 A

3.0 A

GLM75E

+5.1 V

8 A

10 A

+24 V

2.5 A

2.5 A

-15 V

1.0 A

1.0 A

+15 V 2.5 A

3.0 A

GLM75F

+5.1 V

8 A

10 A

+15 V

2.5 A

3.0 A

-5 V

1.0 A

1.0 A

-15 V

2.5 A

3.0 A

GLM75H

+5.1 V

8 A

10 A

+15 V

2.5 A

3.0 A

-15 V

1.0 A

1.0 A

+15 V 2.5 A

3.0 A

GLM75J

+5.1 V

8 A

10 A

+12 V

2.5 A

3.0 A

-12 V

1.0 A

1.0 A

5 V

2.0 A

3.0 A

GLM75P

+5.1 V

8 A

10 A

+24 V

4.0 A

4.0 A

-12 V

1.0 A

1.0 A

+12 V 2.5 A

3.0 A

Notes:
1.

Model may be followed by –L for chassis bracket, –C or –LC for chassis/cover, or –V for Voltage Adj. Pot (+5.1V).

2.

Maximum ratings for 0 CFM airflow without chassis/cover.

3.

Maximum ratings for 26 CFM airflow.

4.

Maximum Operating Relative Humidity 96 %, no condensation.

5.

Contact Condor Technical Support for airflow requirements when using chassis/cover option.

6.

Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of
power.

CERTIFICATION: All models are Certified to be in compliance with the applicable requirements of UL
2601-1, CSA 22.2 No. 601.1, EN 60601-1, and IEC 60601-1. Refer to the safety agency certificates for
details.

CLASSIFICATION:

(5.1) Protection against electric shock = Class I

(In accordance with (5.2) Degree of protection against electric shock = Signal output or intermediate

sub-clause 5

(5.3) Protection against harmful ingress of water = Ordinary (no protection)

of IEC 60601-1)

(5.5) Have not been evaluated for use in the presence of a flammable anaesthetic
mixture with air, oxygen, or nitrous oxide. This evaluation is to be made on the
end equipment by the OEM.

(5.6) Mode of operation = Continuous

SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole
responsibility that all models listed above are in conformity with the applicable requirements
of EN 60950 following the provisions of the Low Voltage Directive 73/23/EEC.

GROUNDING: The Earth (ground) terminal J1, pin 1, must be bonded to Protective Earth in the end
application to preserve the intended safety. Using the Earth terminal on the supply for grounding the end
product’s protective earthing terminal is not recommended. A separate dedicated protective earthing point
should be used.

OUTPUTS: All output commons should be connected to Protective Earth in the end application. The
output(s) are intended for Protectively Earthed Signal Output and Intermediate Circuits only. The output(s)
are not acceptable for patient connection without additional isolation. All DC outputs are SELV under
normal and single fault conditions.

41-34310-0001 Rev. J

Page 1 of 2

GLM75 MULTI-OUTPUT SERIES

INSTALLATION INSTRUCTIONS