SL Power Electronics GLC75 Single Output User Manual
SL Power Electronics Equipment
SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
MODEL NUMBERS: GLC75-X where X represents the output voltage, which may be any number from 5 thru 28. Models
may be followed by suffix –L to indicate optional chassis is provided and/or -XXX to indicate value added configurations that
have no impact on safety which may be any number from 001 thru 999 and/or G to indicate compliance to RoHS.
RATINGS:
Input: 100-240 V ac, 3.0 A, 50/60 Hz
Output: 5 thru 28 V, 20 thru 4 A
Ratings for output voltages 5 thru 11
Ratings for output voltages 12 thru 28
70 W maximum, convection cooled.
75 W maximum, convection cooled.
100 W maximum, with a minimum of 26 CFM airflow.
110 W maximum, with a minimum of 26 CFM airflow.
Notes:
1. Maximum ambient temperature for rated output power is 50 °C.
2. Maximum Operating Relative Humidity 96 %, no condensation.
3. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION: SL Power Electronics Corp. declares under our sole responsibility that all
models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions
of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable
requirements of UL 1950, CSA 22.2 No. 60950 (L3M1), and EN 60950-1 for Pollution Degree 2 environment
and Class I TN-S power systems. The outputs of the supplies meet the requirements for SELV and are not an energy hazard.
GROUNDING: The Earth (ground) terminal J1, pin 1, must be bonded to Protective Earth in the end application to preserve
the intended safety. Using the Earth terminal on the supply for grounding the end product’s protective earthing terminal is not
recommended. A separate dedicated protective earthing point should be used.
SPACINGS: The required creepage and clearance distances from primary circuits to ground and secondary circuits must be
maintained after installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the applicable safety
standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature
and the availability, amount, direction and/or restriction of airflow influence the temperatures of these components.
WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit component(s). Repair
must be performed by SL Power Electronics Corp. authorized personnel. Fuse F1 must be replaced with T 3.5A 250V, 2AG,
UL/CSA type.
WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, and printed wiring traces.
MATING CONNECTORS
J1 Amp Housing 640250-5 Pin 770522-1
J2 Amp Housing 640250-9 Pin 770522-1
CAUTION: Do not exceed 5 A per contact.
SL Power Electronics Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are
carried out by other than authorized agents of SL Power Electronics Corp., or b) the installation of the supply is not in accordance with these installation
instructions and the applicable UL, CSA, and EN/IEC safety standards.
41-34282-0001 Rev. H 09/14/06
GLC75 SINGLE OUTPUT SERIES
INSTALLATION INSTRUCTIONS
C O N N E C T I O N S
J1 Pin
AC Input
J2 Pin
DC Output
J2 Pin
DC Output
1
Ground
1
+ Output
6
- Output
3
Neutral
2
+ Output
7
- Output
5
Line
3
+ Output
8
- Output
4
+ Output
9
Power Fail
5
- Output
Attention, Consult
Accompanying Documents
Alternating Current
Attention, Dangerous Voltages
Earth (Ground)
EXPLANATION OF SYMBOLS
Direct Current