OVERVOLTAGE PROTECTION: The output is monitored for an overvoltage condition. In some
applications where an overvoltage condition could result in a hazard as defined in applicable safety
standards, redundant or additional overvoltage protection may be required. Consult factory for details.
DIELECTRIC STRENGTH TEST CAUTION: When performing Dielectric Strength Tests,
catastrophic failure of the unit may result if a Dielectric Strength test voltage greater than 1800 Vac is
applied between primary and secondary circuits. The components providing isolation from primary to
secondary cannot be tested while installed in the power supply without overstressing basic (primary to
ground) insulation. All isolating components are individually 100% tested at 4800 Vac prior to
installation.
MAINTAINING ISOLATION: The creepage distance between primary and ground is 4 mm minimum;
between primary and secondary circuits is 8 mm minimum. Secondary to ground creepage is not defined
or controlled. The output is bypassed to ground with a capacitor. The required creepage and clearance
distances from primary circuits to ground and secondary circuits must be maintained after installation to
preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in
the applicable safety standards, must not be exceeded after installation to preserve the intended safety.
The output power, ambient air temperature and the availability, amount, direction and/or restriction of
airflow influence the temperatures of these components.
CONNECTIONS
Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other
than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA,
and EN/IEC safety standards.
41-35163-0001 Rev. A 9/24/01
Page 2 of 2
J1 AC Input
J2
Function
1 Line
1,2,8,9
+24 V dc Output
2 Neutral
3,4,10,11
Common
3 Earth
5
N/C
6
AC Good
7
AC Good Return
12
N/C
13
DC Good
14
DC Good Return
MATING CONNECTORS
J1: Molex P/N 44441-2003 (Housing)
Molex P/N 43375-0001 (Pins)
J2: Molex P/N 39-01-2145 (Housing)
Molex P/N 5556/44476 (Pins)
CAUTION: Do not exceed 7 A per pin on connector J2
Attention, Consult
Accompanying Documents
Alternating Current
Attention, Dangerous Voltages
Earth (Ground)
EXPLANATION OF SYMBOLS
- MINT1022 GLM65 Single Output GPC55 GPC40 GECA20 GLC65 Single GLC65 Triple Output GLM65 Triple Output GEM600 GEM750 GLD140 GLD150 GPFC110 GLM75 Single Output GLM50 Triple O/P GPFM250 GPMP600 GPMP700 GSM28 GSM15 G2T60 GPC200 GPC130 GPC140 GLC75 Multiple Output GNT400 GNT30 GLC50 Single GLC50 Triple GPFM115