Installation instructions gpfm125 series – SL Power Electronics GPFM125 User Manual
Page 2

INSTALLATION INSTRUCTIONS GPFM125 SERIES
OVERVOLTAGE PROTECTION: Output #1 on all models, and #2 (GPFM125G & GPFM125H only) are
monitored for an overvoltage condition. In some applications where an overvoltage condition could result in a
hazard as defined in applicable safety standards, redundant or additional overvoltage protection may be required.
Consult factory for details.
CAUTION: When performing Dielectric Strength Tests, catastrophic failure of the unit may result if a
Dielectric Strength test voltage greater than 1800 V ac is applied between primary and secondary circuits. The
components providing isolation from primary to secondary cannot be tested while installed in the power supply
without overstressing basic (primary to ground) insulation. All isolating components are individually 100 %
tested at 4800 V ac prior to installation.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the
applicable safety standards, must not be exceeded after installation to preserve the intended safety. The output
power, ambient air temperature and the availability, amount, direction and/or restriction of airflow influence the
temperatures of these components.
OVERCURRENT PROTECTION: The internal fuse is located in the phase lead only. EN 60601-1 requires
that both supply leads (phase and neutral) be protected against overcurrent. Complete overcurrent protection
must be provided in the host equipment. Fuse ratings must not exceed that
specified for the internal fuse, must meet the requirements of EN 60601-1,
and be acceptable for the country in which the host equipment is to be
installed.
WARNING! RISK OF FIRE! A blown internal fuse is an indication of
catastrophic failure of circuit component(s). Refer to fuse marking on the
supply for rating. Repair must be performed by Condor authorized
personnel.
WARNING! SHOCK HAZARD! Dangerous voltages are present on
some components, printed wiring traces and heatsinks.
C O N N E C T I O N S
J1 Pin
AC Input
J3 Pin
DC Output
J2 Pin
DC Output
1
Line
1
Output #4 (-)
1
Power Fail
3
Neutral
2,3,4
Output #1 (+)
2
- Sense #1
5
Ground
5,6,7,8,9
Common
3
+ Sense #1
10,11
Output #2 (+)
4
Common
12
Output #3 (+)
13
Output #3 (Rtn)
MATING CONNECTORS
J1 Amp Housing 640250-5 Contact 770476-1
J2 Amp MTA-100 Receptacle
J3 Amp Housing 1-640250-3 Contact 770476-1
CAUTION: Do not exceed 5 A per contact on J3.
Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other
than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA,
and EN/IEC safety standards.
41-34961-0001 Rev. C 02/07/01
Page 2 of 2
Attention, Consult
Accompanying Documents
Alternating Current
Attention, Dangerous Voltages
Functional Earth (Ground)
EXPLANATION OF SYMBOLS
Direct Current