SL Power Electronics GPFM1200 User Manual
Page 2

TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in
the applicable safety standards, must not be exceeded after installation to preserve the intended safety.
The output power, ambient air temperature and the availability, amount, direction and/or restriction of
airflow influence the temperatures of these components.
FUSING: The internal fuse is located in the phase lead only. UL 2601-1, CAN/CSA 22.2 No. 601.1-
M90, EN 60601-1, and IEC 60601-1 requires that both supply leads (phase and neutral) be protected
against overcurrent except for permanently installed equipment. Complete overcurrent protection must
be provided in the end-use equipment. Fuse ratings must not exceed that specified for the internal fuse.
A blown fuse is an indication of catastrophic failure of circuit component(s). Repair must be performed
by Condor authorized personnel. Refer to fuse markings for type and rating.
WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, printed wiring
traces and heatsinks.
C O N N E C T I O N S
Attention, Consult
Accompanying Documents
Alternating Current
Attention, Dangerous Voltages
Earth (Ground)
EXPLANATION OF SYMBOLS
Direct Current
Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other
than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA,
and EN/IEC safety standards.
41-35221-0001 Rev. A 12/13/01
Page 2 of 2
TB1 AC Input
J2
DC Output J203 Signals/DC Output
1
Line
5, 6, 7, 12, 13, 14 +48 V
1
+12 V (Aux)
2
Neutral
1, 2, 3, 8, 9, 10
Common
2
Fan Fail
3
Earth
3
Over Temp
4
AC Fail
5
Inhibit
6
Return
7
Master Enable
MATING CONNECTORS
J2:
Molex P/N 39-01-2145 (Housing)
Molex P/N 39-00-0038 (Pins)
J203: Molex P/N 50-37-5073 (Housing)
Molex P/N 08-70-1039 (Pins in Reel)
CAUTION: Do not exceed 5 A per pin on connector J2