SL Power Electronics GLM75 Single Output User Manual
Page 2

CAUTION: When performing Dielectric Strength Tests, catastrophic failure of the unit may result if a
Dielectric Strength test voltage greater than 1800 V ac is applied between primary and secondary
circuits. The components providing isolation from primary to secondary cannot be tested while installed
in the power supply without overstressing basic (primary to ground) insulation. All isolating
components are individually 100 % tested at 4800 V ac prior to installation.
ISOLATION: The creepage distance between primary and ground is 4 mm minimum; between primary
and secondary circuits is 8 mm minimum. Secondary to ground creepage is not defined or controlled.
The output common is bypassed to ground using a 0.01 µF 1 kV capacitor. The required creepage and
clearance distances from primary circuits to ground and secondary circuits must be maintained after
installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in
the applicable safety standards, must not be exceeded after installation to preserve the intended safety.
The output power, ambient air temperature and the availability, amount, direction and/or restriction of
airflow influence the temperatures of these components.
OVERCURRENT PROTECTION: The internal fuse is located in the phase lead only. UL 2601-1,
CSA 22.2 No. 601.1, EN 60601-1, and IEC 60601-1 requires that both supply leads (phase and neutral)
be protected against overcurrent except for permanently installed equipment. Complete overcurrent
protection must be provided in the end equipment. Fuse ratings must not exceed that specified for the
internal fuse, must be acceptable for the country in which the end equipment is to be installed.
WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit
component(s). Repair must be performed by Condor authorized personnel. Refer to fuse marking on the
supply for rating.
WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, and printed
wiring traces.
MATING CONNECTORS
J1 Amp Housing 640250-5 Pin 770522-1
J2 Amp Housing 640250-9 Pin 770522-1
CAUTION: Do not exceed 5 A per contact.
Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or
repairs are carried out by other than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these
installation instructions and the applicable UL, CSA, and EN/IEC safety standards.
41-34470-0001 Rev. F
Page 2 of 2
J1 Pin
AC Input
J2 Pin
DC Output
J2 Pin
DC Output
1
Ground
1
+ Output
6
- Output
3
Neutral
2
+ Output
7
- Output
5
Line
3
+ Output
8
- Output
4
+ Output
9
Power Fail
5
- Output
Attention, Consult
Accompanying Documents
Alternating Current
Attention, Dangerous Voltages
Earth (Ground)
EXPLANATION OF SYMBOLS
Direct Current