Operation

The front panel user interface consists of 6 buttons. The functions assigned to control buttons
depend on the mode selected.

Operating modes

Normal or ‘locked’ mode is the normal operating mode. Configuration or ‘menu’ mode provides
access to configuration menus.

Normal mode

In normal use, the configuration menu will be locked to prevent inadvertent operation and
configuration menus are not available.
The main ‘normal’ mode controls are as follows:

Select Parameter buttons move channel-select cursor to select phase bar source

Lock button resets the peak hold indicators when pressed briefly

Lock button enters ‘menu’ mode when held down for about three seconds

Menu mode

To enter menu mode from normal mode (with the red Lock LED off) hold the Lock button down for
about 3 seconds. The configuration or ‘menu’ mode will be entered, on-screen menus will appear
and the red Lock LED will illuminate. If the Lock button is held down again, any changed settings
will be saved and the MADI-XX will return to normal meter mode.
The menu mode will return to the last menu item visited provided the unit has not been reset or
switched off since a configuration menu was last accessed.

The main ‘menu’ mode controls are as follows:

 Function scrolls menu cursor up and down to select function

 Select Parameter keys (<>) selects settings to apply to chosen parameter; also selects

main menu when menu name is highlighted

 Insert On + Select Parameter (INS + <>) selects main menu page

 Insert On + Lock confirms action in some menus

 Lock button leaves ‘menu’ mode and saves settings when held down for about three

seconds